Navier-Stokes NACA Regression Tests
General Case Information
General Case Information
Inputs:
- Common flow parameters:
- Freestream Mach number: M ∞ = 0.5
- Angle of attack: α = 0 °
- Total pressure: Pt =
- Total temperature: Tt =
- Static temperature:
- CFL: 1030
- Common solver parameters:
- Equation Set: NavierStokes2d
- Preconditioning:
- Outer GMRES iterations (no. restarts): 20
- Inner GMRES iterations (no. Krylov vectors): 200
- Nonlinear Solver = Newton
- PSequencing: False
Inputs:
Tested Outputs:
- Common flow parameters:
Representative Solution:
Specific Test Case information
Specific Test Case information
Newton-GMRES-ILU
Job File: naca_NavierStokes2d_Newton_GMRES_ILU_TEST.job
- General Case Information
- Basis Type: Hierarchical
- SolutionOrder: 2
- Linear Solver Information
- Preconditioner: Incomplete LU
- Preconditioner Side: Left
- Reordering type: MDF
Newton-GMRES-ILUT
Job File: naca_NavierStokes2d_Newton_GMRES_ILUT_TEST.job*
- General Case Information
- Basis Type: Hierarchical
- SolutionOrder: 2
- Linear Solver Information
- Preconditioner: Threshold-based Incomplete LU (ILUT)
- Preconditioner Side: Left
- Reordering type: MDF
- Drop threshold: 10 -6
Viscous Discretization (BR2) - Flux Coefficient
Job File: naca_NavierStokes2d_AuxVariable_FluxCoeff_TEST.job
- General Case Information
- Basis Type: Hierarchical
- SolutionOrder: 2
- Linear Solver Information
- Preconditioner: Incomplete LU
- Preconditioner Side: Left
- Reordering type: MDF
- Linear Solver Information
Viscous Discretization (BR2) - Gradient
Job File: naca_NavierStokes2d_AuxVariable_Gradient_TEST.job
- Nonlinear solver:
- Newton
- Preconditioner:
- Block Jacobi (right)
Unified Adaptation
Job File: naca_NavierStokes2d_UniAdapt_TEST.job
- Nonlinear solver:
- Newton
- Preconditioner:
- Block Jacobi (right)