You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 7 Next »

The following selection, cuts will be applied to W, Z-analysis and not varied unless explicitly stated

  1. Run selection: use SL09b muDst after BHT3 'notch' problem was fixed, beginGMT= 2009-03-28 12:34:27, comprising ~80% of recorded data
    • F10448 - F10536
    • R10087001 - R10103046
      • skip runs w/ badly functioning TPC (~no vertices found) : R10084013, R10088103, R10081024, R10095032, R10085022, R10088060, R10085103, R10087007, R10093049, R10085118
  2. run analysis on muDst and access TRG,TPC,BTOW,BSMD info directly from muDst containers, apply calibrations from DB 'by hand' (no use a2e makers, point makers, etc)
  3. Trigger bits
    1. BHT3 trig ID: 23054[01] or small IDs

    2. L2W trig ID: 23060[01] or small IDs

    3. L2-bits: ET>13 GeV accept
  4. Reco prim vertex selection
    1. rank>=0
    2. | z-vertex | <80 cm
  5. Reco TPC track selection
    1. prim tracks belong to selected prim vertex
    2. flag=301 for primary or 101 for global component
    3. nFitPoints>20 ??
    4. nFit/nPoss>0.51
    5. drop track if last point belong to one of the 'worse' 3 sectors:
      • West TPC sector 11, phi =[1.9,2.3] rad

      • West TPC sector 4, phi =[-0.7, -0.3] rad

      • East TPC sector 21, phi =[-0.7, -0.3] rad

  6. BTOW: use ideal gains & actual status tables & pedestals
    1. assume tower is dead if status!=1
    2. assume tower ADC=0 if (rawADC-ped)< 3* sigPed
  7. BSMD use Willi's 2009 calibration
    1. use relative gains, DB flavor=Wbose
    2. use status bits from DB , flavor=ofl
    3. assume strip is dead if status not in range [1,......???] ???

    4. assume tower ADC=0 if (rawADC-ped)< 3* sigPed
  • No labels