You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 8 Next »

10/27

Updated specifications:


SpecificationValue
Contraction Area Ratio8.085

Chamber Diameter

3.25 in (min)
Throat Diameter1.143 in (min)

Characteristic Length

63 in

Chamber Length

6 in

Contraction Angle

30 deg
Expansion Angle15 deg
Exit Diameter2.576 in
Exit Pressure14.12 psi

Chamber Pressure

460 psi
Mass Flow1.22 kg/s
Exit Mach Number2.723



  • Contraction ratio issue solved. Now have chosen maximum acceptable value of 10
  • Exit pressure is 97329.71 Pa, ideal calculations, see if matches RPA
  • nozzle sized 1.5 mm less to account for expected 0.1 mm/s erosion
  • exit area also sized down to match nozzle (with slight round up)


To do:

  • Thermal analysis
  • Graphite and phenolic erosion modeling
  • O-ring sizing
  • Slides


References:

https://ocw-mit-edu.ezproxyberklee.flo.org/courses/16-512-rocket-propulsion-fall-2005/resources/lecture_3/ (Exit pressure)

https://www.eucass.eu/doi/EUCASS2017-474.pdf (L*, contraction ratio)

https://ntrs.nasa.gov/api/citations/19710019929/downloads/19710019929.pdf (angles, general)

https://yang.gatech.edu/publications/Journal/JPP%20(2008,%20Thakre).pdf(graphite)