These motors are tested on "Henrietta" our yellow 54mm and 98mm test stand.
Test # | Date | Site | Result |
---|---|---|---|
XB-54-1G #3 | Various | Bldg. 37 | Low pressure initial test runs, Test 3 is the only one we found data for |
XB-98-1G #1 | 3-4-2017 | Crow Island, MA | |
XB-98-1G #2 | 3-4-2017 | Crow Island | |
XB-98-1G #3 | 3-4-2017 | Crow Island | |
XB-98-1G #4 | 3-4-2017 | Crow Island | |
XB-98-1G #5 | 3-4-2017 | Crow Island | |
XB-98-1G #6 | 3-4-2017 | Crow Island | |
XB-98-4G #1 | 3-24-2017 | Crow Island | Undetected stress concentrator in nozzle lead to a cracked nozzle. |
XB-98-4G #2 | 4-2-2017 | Crow Island | Poor sealing on thermal liner lead to runaway burn-through |
XB-98-4G #3 | 9-23-2017 | Crow Island | Full Duration |
...