...
These motors are tested on "Henrietta" our yellow 54mm and 98mm test stand.
Test # | Date | Site | Result | |
---|---|---|---|---|
XB-54-1G #X#3 | Various | Bldg. 37 | Low pressure initial test runs, Test 3 is the only one we found data for | |
XB-98-1G #1 | 3-4-2017 | Crow Island, MA | ||
XB-98-1G #2 | 3-4-2017 | Crow Island | ||
XB-98-1G #3 | ||||
XB-98-1G #4 | ||||
XB-98-1G #5 | ||||
XB-98-1G #6 | ||||
XB-98-4G #1 | 3-24-2017 | Crow Island | Undetected stress concentrator in nozzle lead to a cracked nozzle. | |
XB-98-4G #2 | 4-2-2017 | Crow Island | Poor sealing on thermal liner lead to runaway burn-through | |
XB-98-4G #3 | 9-23-2017 | Crow Island | Full Duration |
...