Full set cuts applied to W-algo ver 4.1
(this list is consistent with common set of cuts)
- Run selection: setABCD.runList, available # of events: input=1.55e6, L2wET=1.17e6
- RHIC fill range: F10383 - F10536
- STAR run range: R10076134 - R10103046
- skip runs w/ badly functioning TPC (~no vertices found) : R10084013, R10088103, R10081024, R10095032, R10085022, R10088060, R10085103, R10087007, R10093049, R10085118
- run analysis on muDst's
- access TRG,TPC,BTOW,BSMD directly from muDst containers
- apply calibrations from DB 'by hand' in analysis code
- Trigger bits requirement
- BHT3 trig ID: 23054[01] or small IDs for some runs
- L2W trig ID: 23060[01] or small IDs
- L2-bit1 (on line value was ET>13 GeV)
- count L2-bit0 (random accept of BHT3) for absolute 'seen' cross section
- Reco prim vertex requirements
- rank>0
- | z-vertex | <100 cm
- Reco TPC track requirements
- prim tracks belong to selected prim vertex
- (flag=301 for primary) or (flag=101 for global) component
- if primary is valid but its global pointer is NULL skip the primary track, but keep the rest of the event
- nFit/nPoss>0.51
- glob PT>1 GeV/c
- if track PT>10 GeV/c assume it is 10 GeV/c
- for high energy electron candidate require additional
- nFitPoints>=15
- 1st hit Rin<90 cm
- last hit Rout>170 cm
- do not use TPC dEdX information for SL09b events
- BTOW: use ideal gains, actual status tables & pedestals , 'ofl' flavor for all, no time stamp set in the user code
- assume tower is dead if status!=1
- assume tower ADC=0 if (rawADC-ped)< [3*sigPed or 8 counts]
- drop event if max tower ADC <200
- 2x2 cluster ET > 15 GeV, cluster must contain tower pointed by the track
- 2x2/4x4 ET >0.95
- 2x2/near-cone ET(BTOW+TPC) >0.90, near-cone has delR=0.7 around track
- away-cone ET(BTOW+TPC) <8 GeV , away-cone has only delPhi=0.7 around (-track), no eta cut,