Goal:

We discuss the evolution of CTI and its impact on spectral resolution for X-ray CCDs in different orbital environments.  We specifically prepare
models of the energy scale and resolution as a function of the background, CCD type (FI vs. BI), and application of charge injection, considering
energies spanning the CCD range.

Outline:

  • CTI evolution (energy scale, FWHM)
         - effects of different radiation environments
         - effects of SCI
         - calibration sources from corners (Mn K alpha, akin to LaMarr 2008)
              - compare ACIS and XIS
         - calibration sources (all energies?) across FOV
              - ACIS only
         - celestial calibration sources (1 keV, 6 keV) across FOV
              - Cygnus Loop, Perseus, E0102, N132D, other clusters
         - separate CTI from electronics gain
              - verify gain change negligible
              - checker-flag CI (Ozawa 2009)
              - Cygnus Loop/Perseus at different roll angles (XIS)
              - (are we interested in electronics performance?)
  • CTI of FI vs. BI
         - soft proton damage
         - effects of BG sac charge (Grant 2005 SPIE, LaMarr 2008 SPIE)
  • about the instruments
    • first describe each separately (label CCDIDs)
    • then similarities/differences between ACIS/XIS that impact CTI (just the instruments and operation, no environment yet) in a table and summarize in text
      • initial pre-launch CTI, ACIS BI > XIS BI, XIS FI > ACIS FI
      • Transfer speeds, fast transfer (image-to-framestore) serial transfer not the same
      • Frame time, 3.2s vs 8s
      • Focal plane temperature, -90C vs -120C
  • about the orbits and backgrounds
    • steal from Bev's paper
    • steal from O'Dell, Markevitch papers
  • about the calibration sources
    • ACIS, Fe55 with Al&Ti (Fe-L), uniform illumination, getting pretty wimpy, only sampled twice per orbit
    • XIS, Fe55 in corners, getting wimpy, continuously sampled (except SAA)
    • measure Fe55 half-life extremely well
  • Measuring CTI, ACIS vs XIS (methodology)
    • ACIS, fit center pixel pulseheight vs ccdy/ccdx (binning/fitting details too)
    • XIS, fit good grades summed pulseheight from top cal source corners
    • (should we process ACIS the same way as XIS for comparison? only use center pixels?)
    • only use Mn K alpha
  • CTI evolution, plots of measured CTI vs time
    • for ACIS, apply corrections for temperature and sacrificial charge
    • not done for XIS; temperature is stable, background is integrated over 1 day = 16 orbits
  • compare differences in rate of CTI increase (and shape?)
    • (no parallel vs serial)
    • FI vs BI
    • low vs high orbit
    • with and without CI (for XIS, when possible)
  • charge trailing vs time
    • trailing fraction shows how initial ACIS from low energy protons is different from ongoing, higher energy particle damage
    • metric is average lost charge of all events divided by average trailed charge of all events

*FWHM evolution, plots of measured FWHM vs time

    • ACIS and XIS can pretty much measure this one the same way
    • (G02346, summed pulseheights, fit Gaussians, etc.)
    • discussion related to all the above stuff
    • somewhat more complicated to link to physical causes w/ charge trailing, multi-pixel events
  • relate CTI and FWHM increases
    • depend on BI/FI; are ACIS/XIS different?
  • relate CTI/FWHM increase to measures of particle fluence, type
    • maybe beyond scope of this paper)