RAID configuration for Thalia production cluster 

The Thalia production cluster needed large amounts of disk storage available locally to hold its content.  To provide this, a RAID array was built in the cluster, as follows:

 Base hardware for the Thalia production cluster in the HP DL380 G5.  It has drive bays for 8 SATA or SAS drives.  We had it populated with 8 146 Gb dirves, built into 2 RAID arrays: A  

Panel

A RAID 1 array of 2 disks, with a total of 140 Gb, for the OS.

A RAID 5 array of 6 disks,  4 for data, 1 for parity, and 1 hot spare, with a total of 538 Gb, mounted at /home.  It holds the picture content files.

If a drive in the RAID 5 array fails, the spare disk will automatically be used as a replacement for the failed drive. Having the parity drive in place means that 2 drives will have to fail before data lose occurs.