17 Feb 2011 - ACIS peaks and sigmas
24 Mar 2011 - ACIS line fluxes
04 May 2011 - XIS peaks versus COR
04 May 2011 - IACHEC plots: ACIS & XIS peaks, FWHMs & line fluxes
21 Jun 2011 - Is line centroid a good proxy for CTI?
17 Oct 2011 - Figures for paper?
31 Oct 2011 - Trailing charge
31 Oct 2011 - Figures for paper
21 Nov 2011 - Schematic figures for paper
02 Dec 2011 - CTI change at -120C and -90C on ACIS

...

Anchor
anchor1
anchor1
17 Feb 2011 - Catherine's attempt to duplicate Bev's monthly XIS plots for ACIS I3 (FI) and S3 (BI). Each data point is a fit to 0.1 years worth of cold ACIS calibration source data, filtered to include only the upper corner regions like XIS and grades G02346. After some testing as to which fitting procedures were less sensitive to background variations (important for ACIS probably not as much for XIS), and robust against low signal-to-noise data, I chose to use a Gaussian plus a linear background component (mpfitfun.pro with some limits to prevent non-physical fits).

...


ACIS schematic PS


XIS schematic PS

...

Anchor
anchor10
anchor10
Dec 2, 2011 - Catherine

CTI change at -120 and -90C on ACIS

At my review, Mark and I talked about the problem of separating the different radiation environment from the different focal plane temperatures. I remembered that we had taken data with ACIS at -90C at two different times, in Sept 1999 and Aug 2005, so we can at least see how different the CTI evolution is on ACIS at both temperatures.

Image Added
ACIS peak vs temperature for S2 and S3

...

Attachments

...