  • Contraction ratio issue solved. Now have chosen maximum acceptable value of 10, and a current value of 9.55
  • Chamber diameter is 3.5 in, which is the space that the injector needs
  • Throat diameter of 1.1326 in 
  • Mass flow is 1.2 kg
  • Chamber pressure of 460 (do calculations with 10% less)
  • Exit pressure of 97329.7095 71 Pa 
  • 30 deg contraction and 15 deg expansion angles