Item | Description |
---|---|
Description | Payload Stack hardware not integrated. Risk to critical mission data |
Where found | Rocket Central |
Suggested Fix | Bring Payload stack hardware to RC |
Implementation | Hardware coming with Diane R on 7/34 |
Item | Name | Date/time |
---|---|---|
Found by | Andrew A | 6/30/2019, 12pm |
Assigned to | Diane R | 6/30, 9pm |
Completed by | ||
Verified by |
...
Item | Description |
---|---|
Description | Thermocouples not integrated. Risk to critical mission data |
Where found | Rocket Central |
Suggested Fix | Use Proline to epoxy in TC's to NC tip. |
Implementation |
|
Item | Name | Date/time |
---|---|---|
Found by | Andrew A | 6/30/2019, 12pm |
Assigned to | Juan S | 6/30, 9pm |
Completed by | ||
Verified by |
...
Item | Description |
---|---|
Description | LE Hardware not integrated (Including LE and shield). Risk to critical mission data |
Where found | Rocket Central |
Suggested Fix | Bring LE hardware to RC |
Implementation | -- LE Hardware is now in RC (7/2, 8pm) |
Item | Name | Date/time |
---|---|---|
Found by | Andrew A | 6/30/2019, 12pm |
Assigned to | Andrew R | 6/30, 9pm |
Completed by | ||
Verified by |
...
Item | Name | Date/time |
---|---|---|
Found by | Andrew A | 6/30/2019, 12pm |
Assigned to | Zack H, Max K | 6/30, 9pm |
Completed by | ||
Verified by |
Issue 8: 2S Lipo
Status: In progressCompleted
Links:
Photos:
Item | Description |
---|---|
Description | 2S lipo may be swollen. Risk to electronics fire and loss of mission |
Where found | Rocket Central |
Suggested Fix | Check if swollen, replace if swollen |
Implementation | Disassembled to check if swollen. Battery not swollen, 3D printed plastic had corners nominally bent during printing. |
Item | Name | Date/time | |
---|---|---|---|
Found by | Andrew A | 6/30/2019, 12pm | |
Assigned to | Zack H, Max K | Andrew R | 7/2, 8pm6/30, 9pm |
Completed by | Andrew R | 7/2, 8:15pm | |
Verified by | Andrew A | 7/2, 8:20pm |
Issue 9: TD Retention (WIP)
...